• Four operating modes: - Panic button - ON / OFF (ON / OFF) - Retention - Pulse: 1 second • Supply voltage: 12-16VDC; • Consumption in stand-by mode: 28mA/12V; • Consumption Active mode: 39mA/12V; • Scope, patented technology: up to 250m; • Radiating power ≤ 10mW • Frequency: 433.92MHz; ...
• Four operating modes: - Panic button - ON / OFF (ON / OFF) - Retention - Pulse: 1 second • Supply voltage: 12-16VDC; • Consumption in stand-by mode: 46mA/12V; • Consumption Active mode: 73mA/12V; • Scope, patented technology: up to 250m; • Radiating power ≤ 10mW • Frequency: 433.92MHz; ...
• Five operating modes: - Panic button - ON / OFF (ON / OFF) - Retention - Pulse: 1 second - Switch to regular mode: 1-300 sec. • Supply voltage: 12-16VDC; • Consumption: - Stand-by mode: 14mA/12V; - Active mode: 27mA/12V; • Scope, patented technology: up to 500m; • Security code: KEELOQ ...
• Five operating modes: - Panic button - ON / OFF (ON / OFF) - Retention - Pulse: 1 second - Switch to regular mode: 1-300 sec. • Supply voltage: 12-16VDC; • Consumption: - Stand-by mode: 15mA/12V; - Active mode: 39mA/12V; • Scope, patented technology: up to 500m; • Security code: KEELOQ ...
• Five operating modes: - Panic button - ON / OFF (ON / OFF) - Retention - Pulse: 1 second - Switch to regular mode: 1-300 sec. • Power supply: AC / DC 24V ± 10%; • Consumption: - Stand-by mode: 18mA/24V; - Active mode: 31mA/24V; • Scope, patented technology: up to 500m; • Security code: ...
• Five operating modes: - Panic button - ON / OFF (ON / OFF) - Retention - Pulse: 1 second - Switch to regular mode: 1-300 sec. • Power supply: AC / DC 24V ± 10%; • Consumption: - Stand-by mode: 19mA/24V; - Active mode: 42mA/24V; • Scope, patented technology: up to 500m; • Security code: ...
• Four operating modes: - ON / OFF (ON / OFF) - Retention - Pulse: 1 second - Switch to regular mode: 1-240 sec. • Supply voltage: 12-16VDC; • Consumption: - Stand-by mode: 15mA/12V; - Active mode: 29mA/12V; • Scope, patented technology: up to 500m; • Security code: KEELOQ - leaping 64 bit...
• Four operating modes: - ON / OFF (ON / OFF) - Retention - Pulse: 1 second - Switch to regular mode: 1-240 sec. • Power supply: AC / DC 24V ± 10%; • Consumption: - Stand-by mode: 17mA/24V; - Active mode: 33mA/24V; • Scope, patented technology: up to 500m; • Security code: KEELOQ - leaping...
• PASP1 plastic panic button • Material: heavy-duty plastic • Configuration (open / closed contact): Optional • Number of terminals: 5 • Return to normal: With key • Visual indication window • Dimensions: 70mm x 54mm x 27mm • Maximum Voltage: 50vdc • Maximum current: 500mA...